Bücher

Artikel 21 bis 27 von 27 gesamt

pro Seite
Seite:
  1. 1
  2. 2

In aufsteigender Reihenfolge
  1. Availability of Power Plants 2012 – 2021, Edition 2022 (KISSY database evaluation) - ebook

    Availability of Power Plants 2012 – 2021, Edition 2022 (KISSY database evaluation) - ebook

    Bestell-Kennz.: VGB-TW-103Ve-2022-ebook
    zzgl. Steuern: 340,00 € Inkl. Steuern: 363,80 € ab: 181,90 €

    Since 1970 VGB has collected data about power plants based on standardized definitions, calculation methods, and recording procedures, among others in the database KISSY.

    This report (edition 2022) presents the analysis about availability and utilization for the period 2012 - 2021.

  2. Verfügbarkeit von Kraftwerken 2012 - 2021, Ausgabe 2022 (KISSY Datenbank-Auswertung) - ebook

    Verfügbarkeit von Kraftwerken 2012 - 2021, Ausgabe 2022 (KISSY Datenbank-Auswertung) - ebook

    Bestell-Kennz.: VGB-TW-103V-2022-ebook
    zzgl. Steuern: 340,00 € Inkl. Steuern: 363,80 € ab: 181,90 €

    Mit dem Ziel, den Betrieb von Kraftwerksanlagen und die Anlagen selbst zu bewerten, zu vergleichen und zu optimieren, sammelt VGB seit 1970 nach einheitlichen Definitionen und Ermittlungsverfahren Daten über die Verfügbarkeit und Ausnutzung von Kraftwerken u.a. in der Datenbank KISSY.

    Dieser Bericht (Ausgabe 2022) informiert über die Verfügbarkeit und Nutzung für den Zeitraum 2011 - 2021.

  3. Reliability Indicators with KISSY - VGB Research Project 361 (only PDF-download) - Print

    Reliability Indicators with KISSY - VGB Research Project 361 (only PDF-download) - Print

    Bestell-Kennz.: TW104
    zzgl. Steuern: 450,00 € Inkl. Steuern: 481,50 € ab: 321,00 €

    VGB Power Plant Information System

    This report was created by the VGB European Working Group “Performance Indicators”, in order to support the VGB research project “Reliability Indicators with KISSY” lead by DNV KEMA in close cooperation with VGB PowerTech e.V..

  4. Zentrale Zuverlässigkeits- und Ereignisdatenbank - Mathematical Review of ZEDB Two-Stage Bayesian Model - Print

    Zentrale Zuverlässigkeits- und Ereignisdatenbank - Mathematical Review of ZEDB Two-Stage Bayesian Model - Print

    Bestell-Kennz.: TW802e-ebook
    zzgl. Steuern: 60,00 € Inkl. Steuern: 64,20 €

    Vorwort des Herausgebers

    VGB PowerTech hat eine zentrale Zuverlässigkeits- und Ereignisdatenbank (ZEDB) eingerichtet, in der die Betriebserfahrungen der deutschen Kernkraftwerke, der niederländischen Anlage Borssele und des Kernkraftwerks Gösgen (Schweiz) gesammelt werden, um daraus anlagenspezifische Zuverlässigkeitsdaten für probabilistische Sicherheitsanalysen (PSA) zu ermitteln.

    Publisher's Preface

    VGB PowerTech has set up a centralized Reliability and Event Data Base (ZEDB) which contains a compilation of the operating experiences of all German nuclear power plants, the Dutch unit Borssele and the Swiss unit Goesgen, generated to allow plant-specific reliability data to be determined for probabilistic safety analyses (PSA).

    This publication will be delivered as an ebook (PDF-file).

  5. Recommendations for the operation and monitoring of boiler circulating pumps - Based on extensive follow-up examinations relating to the damage event in 2014 - ebook

    Recommendations for the operation and monitoring of boiler circulating pumps - Based on extensive follow-up examinations relating to the damage event in 2014 - ebook

    Bestell-Kennz.: TW530e-ebook
    zzgl. Steuern: 270,00 € Inkl. Steuern: 288,90 € ab: 192,60 €

    On 12th May 2014 the pressure casing of a boiler circulating pump (BCP) in the hard coal-fired supercritical power station Staudinger, unit 5, failed which led to considerable damage in the power plant [1/1]. As is customary following such severe damage events, the topic was discussed by VGB PowerTech e. V. (VGB) – as the competent international association of power plant operators – who took up the topic, coordinated it and dealt with it within the scope of its responsibility.

  6. Empfehlungen zum Betrieb und zur Überwachung von Kesselumwälzpumpen - Basierend auf den umfangreichen Nachuntersuchungen zum Schadensereignis 2014 - Print

    Empfehlungen zum Betrieb und zur Überwachung von Kesselumwälzpumpen - Basierend auf den umfangreichen Nachuntersuchungen zum Schadensereignis 2014 - Print

    Bestell-Kennz.: TW530
    zzgl. Steuern: 270,00 € Inkl. Steuern: 288,90 € ab: 192,60 €

    Am 12. Mai 2014 kam es im kohlebefeuerten, überkritisch betriebenen 510 MWel Steinkohlekraftwerk Staudinger Block 5 zum Versagen des drucktragenden Gehäuses einer Kesselumwälzpumpe (KUP), das zu erheblichen Schäden im Kraftwerk führte [1/1]. Wie im Anschluss an derartige größere Schadensereignisse üblich wurde das Thema vom VGB PowerTech e. V. (VGB) – als zuständigem internationalen Verband der Energieanlagenbetreiber – aufgenommen, federführend koordiniert und im Rahmen der Zuständigkeit bearbeitet. 

  7. Empfehlungen zum Betrieb und zur Überwachung von Kesselumwälzpumpen - Basierend auf den umfangreichen Nachuntersuchungen zum Schadensereignis 2014 - ebook

    Empfehlungen zum Betrieb und zur Überwachung von Kesselumwälzpumpen - Basierend auf den umfangreichen Nachuntersuchungen zum Schadensereignis 2014 - ebook

    Bestell-Kennz.: TW530ebook
    zzgl. Steuern: 270,00 € Inkl. Steuern: 288,90 € ab: 192,60 €

    Am 12. Mai 2014 kam es im kohlebefeuerten, überkritisch betriebenen 510 MWel Steinkohlekraftwerk Staudinger Block 5 zum Versagen des drucktragenden Gehäuses einer Kesselumwälzpumpe (KUP), das zu erheblichen Schäden im Kraftwerk führte [1/1]. Wie im Anschluss an derartige größere Schadensereignisse üblich wurde das Thema vom VGB PowerTech e. V. (VGB) – als zuständigem internationalen Verband der Energieanlagenbetreiber – aufgenommen, federführend koordiniert und im Rahmen der Zuständigkeit bearbeitet. 

Artikel 21 bis 27 von 27 gesamt

pro Seite
Seite:
  1. 1
  2. 2

In aufsteigender Reihenfolge